Gas Heater Rebate Victoria: VEU Discounts and the 2027 Rental Rule

What can I get off when replacing a gas heater, and what do rentals need from 1 March 2027?

As of November 2026, VEU offers up to $1,610 replacing a room gas heater or up to $5,530 replacing ducted gas with ducted reverse-cycle heating. Amounts are indicative; your accredited provider confirms the discount on the quote. From 1 March 2027, irreparable fixed-heater failure triggers efficient electric replacement. A working compliant heater can stay.

Figures as of November 2026. Updated 13 November 2026.

In this guide
  1. What can I get off when replacing a gas heater, and what do rentals need from 1 March 2027?
  2. What you have now → what you can get off
  3. What must you still pay?
  4. Must a working gas heater be replaced?
  5. What electric heating meets the new rule?
  6. What heating exemptions can apply?
  7. Can renters ask for a heater?
  8. Official sources
  9. Related SettleAU guides

What you have now → what you can get off

As of November 2026, these are indicative household VEU discounts, up to the amounts shown. Your accredited provider confirms the discount on the quote.

What you have nowApproved reverse-cycle replacementAs of November 2026, up to
Room gas heaterRoom reverse-cycle (3–9 kW)$630–$1,610
Hard-wired electric resistance room heaterRoom reverse-cycle (3–9 kW)$840
Room reverse-cycleRoom reverse-cycle (3–9 kW)$210
No decommissioned productRoom reverse-cycle (3–9 kW)$70–$140
Ducted gas4 splits: 1 × 8 kW and 3 × 3 kW$2,520
Ducted gasMulti-split: 1 × 10 kW outdoor unit$2,940
Ducted gasDucted reverse-cycle: 10 / 16 / 22.4 kW$2,520 / $4,200 / $5,530
Central electric resistance ductedDucted reverse-cycle (10–22.4 kW)$5,460
Ducted reverse-cycleDucted reverse-cycle: 10 / 16 / 22.4 kW$490 / $770 / $910
Nothing removedDucted reverse-cycle$410

Installing a new gas space heater earns no VEU discount. Contact an accredited provider before purchase; retrospective discounts are typically not possible.

What must you still pay?

Mandatory minimum contributions changed on 30 September 2026. These amounts include GST and apply per installed product; the actual quote may be higher.

ProductMinimum contribution
Single-split below 10 kW$200
Single-split 10 kW or above$1,000
Multi-split below 10 kW$1,000
Multi-split 10 kW or above$3,000
Ducted$3,000

VEU requires an approved high-efficiency reverse-cycle air conditioner providing heating and cooling, with at least a 5-year home warranty. If replacing a system, the property must be more than 2 years old. Use an accredited provider or an installer working with one.

Must a working gas heater be replaced?

No: a functioning heater meeting the existing minimum standard can stay. If there is no heater, or it is below the current standard, a compliant heater must be installed immediately. Portable heaters do not count.

Right now, the main living area needs a fixed heater in good working order. Current efficient options include a non-ducted air conditioner or heat pump rated at least 2 stars, a gas space heater rated at least 2 stars, ducted or hydronic heating with an outlet in that area, or a solid-fuel appliance.

From 1 March 2027, an existing fixed heater that fails and cannot be repaired must be replaced with energy-efficient fixed electric heating in, or with an outlet in, the main living area. See key dates and the rental standards hub.

What electric heating meets the new rule?

An electric non-portable, non-ducted air conditioner or heat pump needs a GEMS heating rating of at least 2 stars for the climate area. Electric ducted heating needs a GEMS Heating Seasonal Performance Factor of at least 3.2.

One reverse-cycle air conditioner can satisfy both heating and cooling standards. Check the cooling specifications as well; meeting a heating rating alone is not the full check.

What heating exemptions can apply?

CAV lists higher-than-average cost, network augmentation, owners corporation rules, heritage permit refusal, other laws making costs prohibitive and work that is not reasonably practicable. Electrical work and switchboard upgrades are not counted in the higher-cost exemption.

Pre-existing compliant working heating and identical warranty replacement can also qualify. Solid-fuel or LPG systems can be replaced with the identical type. CAV examples include centralised building systems or no outdoor compressor space. A fixed heater in good working order is still required if exempt.

Check the official exemption guidance for the exact conditions and keep evidence. Ask CAV about unusual systems or building constraints.

Can renters ask for a heater?

Installing heating or air conditioning needs permission. A rental provider cannot refuse without good reason a change needed to keep a renter from being too hot or cold, or to reduce energy and water bills. The provider does not have to pay for a renter-requested change.

Read renters’ rights and repair steps and the VEU guide before arranging installation.

Official sources

Figures as of November 2026. This guide uses the fact sheet built on 13 November 2026. Source dates are listed below; a page update does not mean every source was re-checked that day.

General information only: This guide is not legal or financial advice and is not from a government agency. Check the official sources and ask CAV or Tenants Victoria about edge cases.